Test Overview
It is used to evaluate the performance of air intake filters . Below are the key test parameters:
1. Restriction and Differential Pressure Test
· Test Purpose: Measures resistance variations at different airflow rates to plot the resistance-airflow curve.
· Test Method:
o Select five flow rate points between 50% and 150% of the rated flow.
o Record the pressure drop (ΔP) at different flow rates.
· Application: Evaluates airflow capacity and ensures the filter does not excessively restrict engine intake.
2. Initial Efficiency
· Test Purpose: Determines the filter’s efficiency in capturing particles at the start of operation.
· Test Method:
o Uses A4 Fine (fine dust) or A2 Coarse (coarse dust) for testing.
o Adds either 20g of dust or a mass equivalent to six times the flow rate (m³/min) (whichever is greater).
o Weighs the test filter and absolute filter increment, calculating initial efficiency (%).
· Application: Evaluates the initial filtration capability of new filters.
3. Full-Life Efficiency
· Test Purpose: Measures overall filtration efficiency when the filter reaches its final restriction.
· Test Method:
o Dust is continuously introduced until the filter reaches its final pressure drop (e .g., 250 mmH₂O or 2.5 kPa).
o Measures cumulative filtration efficiency over the entire test.
· Application: Provides insight into the filter’s performance over its lifespan.
4. Incremental Efficiency
· Test Purpose: Evaluates filtration efficiency at different loading stages before reaching the final restriction.
· Test Method:
o Efficiency is measured at 10%, 25%, and 50% of the difference between final and initial pressure drop.
o Weighs the test filter and absolute filter, calculating efficiency at each stage.
· Application: Assesses how filtration efficiency changes over time.
5. Dust Holding Capacity Test
· Test Purpose: Measures the total dust mass retained in the filter when it reaches its final restriction.
· Test Method:
o Records the total weight difference of the filter before and after the test to determine its dust holding capacity.
o The test stops when the rated final restriction (e.g., 2.5 kPa) is reached.
· Application: Determines filter longevity and replacement intervals.
Special Advantages
1. Multi-Function Testing Capability
· The equipment supports not only dust holding capacity testing but also initial resistance testing, resistance-airflow curve analysis, and more, meeting various testing requirements .
· Fully automated testing process, reducing manual intervention and improving efficiency and accuracy.
2. Intelligent Testing Process
· Guided testing system, automatically prompting each step to reduce operational difficulty.
· Automatic electronic scale data reading, precise calculations with no need for manual recording or calculations .
· Automatic airflow and pressure detection, starting the test automatically when conditions are met, ensuring reliable data .
3. High-Precision Nozzle Flow Meter
· Automatic nozzle switching, ensuring accurate flow rate measurement for different testing needs.
· One-touch operation, allowing easy selection of standards and test parameters.
4. High Adaptability and Easy Installation
· Compact design, small footprint, suitable for laboratories and industrial applications.
· Easy installation and flexible design, customizable testing solutions.
· Compatible with various shapes and sizes of filters, making testing straightforward.
5. High-Performance Filtration System
· Uses F8 V-bank reinforced absolute filters, ensuring stable operation under specific pressures and providing more accurate test results.
Software and Results
1. Real-Time Monitoring and Data Visualization
· Real-time monitoring of resistance and airflow changes, providing intuitive data feedback.
· Visual data presentation, displaying test curves clearly for easier analysis.
· Multiple alerts and warning functions, reducing human error and simplifying operation.
2. Results Output and Data Management
· Automatically generates complete test reports and print labels in Excel format, allowing users to edit and adjust as needed, with clear data analysis and conclusions.
· Supports customization of special formats and multilingual templates, catering to different customer needs.
· Regular automatic backup of historical data, preventing data loss.
3. Remote Monitoring and Maintenance
· Integrated camera and remote control system, enabling remote operations:
o Remote fault diagnosis
o Remote debugging
Technical Data
Items | Parameter |
Air flow rate | 500~4800m3/h, customized |
Pressure drop | 0~10000 Pa |
Testable filter size | Filter assembly testing is not restricted, filter element testing requires a adapters |
Dust feeder | SC-189, A2/A4 |
Dimension (with FFU) | 6500mm×3500mm×1800mm |
SCPUR: Advanced Testing Solutions – Stability, Convenience, Practicality, Upgrades, and Reliability.
Home Products About Us Application Support Download Knowledge Center Contact Us