How to Choose HEPA Filter Testing Equipment

공유하다:

목차

HEPA testing equipment is not one type of machine. Media development, finished-filter efficiency, factory scan leak testing and installed-filter integrity verification involve different test objects, outputs and instruments. The correct system can be selected only after the test question is clearly defined.

Four test tasks that must be separated

Four test tasks that must be separated

Test Task테스트 항목Primary OutputTypical Equipment
Media R&디Flat-sheet mediaFractional efficiency, 압력 강하, MPPSFilter media tester
Integral efficiencyComplete filterOverall efficiency or penetration and pressure dropFull-size duct test bench
Factory scanFilter face and critical seal areasLocal penetration and leak locationAutomatic scan leak test system
Installed integrityInstalled filter and installation boundaryIntegrity of filter, seals and housing in the fieldPortable aerosol generator with photometer or particle-counter system

How do standards and equipment correspond?

How do standards and equipment correspond?

ISO 29463-3 applies to flat-sheet high-efficiency filter media. ISO 29463-5 covers efficiency testing of complete filter elements near MPPS, while the scan method in ISO 29463-4 is used to locate local leakage. After filters are installed in a cleanroom or controlled environment, the objective changes to verification of the installed filtration system. This is normally performed under ISO 14644-3, a project specification or an industry procedure. A field result does not replace the manufacturer’s classification, and a factory scan cannot prove that the installed system has no bypass leakage.

When is a fixed 0.3 µm test useful?

When is a fixed 0.3 µm test useful?

A fixed-particle-size efficiency or leak check can be useful for fast production quality control. 하지만, if the applicable standard requires testing at MPPS or scanning against local penetration limits, 에이 0.3 µm result alone cannot demonstrate full compliance with ISO 29463 또는 EN 1822. A rapid internal method should be correlated with the standard method, and its purpose should be stated clearly in the report.

Six questions to answer before choosing a system

Six questions to answer before choosing a system

  • Are you testing flat-sheet media or a complete filter?
  • Do you need integral efficiency, local scanning or installed integrity verification?
  • What are the product dimensions, construction, rated airflow and maximum resistance?
  • What target class and edition of the standard apply?
  • Which aerosol and detector will be used, and is the expected downstream concentration measurable?
  • What throughput, 오토메이션, reporting and metrological traceability are required?

Where do SCPUR systems fit?

Where do SCPUR systems fit?

The SC-FT-1406 series is used for efficiency and pressure-drop evaluation of flat-sheet media. 그만큼 SC-L8023 그리고 SC-L8023U are designed for integral efficiency and automatic scan leak testing of complete high-efficiency filters. Installed-filter integrity verification requires portable field instruments and a procedure matched to the project. Providing the filter design, applicable clauses and expected report before quotation is the most reliable way to obtain the right configuration instead of a generic HEPA test bench.

EDITORIAL REFERENCES

Primary Standards Checked

Primary Standards Checked

The following official ISO pages were checked for this rewrite. Formal testing, contracts and compliance decisions should be based on the purchased standard text and the edition specified by the project.

  • ISO 16890-1:2016Technical specifications, requirements and classification system based on particulate matter efficiency for general-ventilation air filters
  • ISO 16890-2:2022Measurement of fractional efficiency and airflow resistance
  • ISO 16890-3:2024Gravimetric efficiency and airflow resistance versus captured test-dust mass
  • ISO 16890-4:2022Conditioning method used to determine minimum fractional test efficiency
  • ISO 29463-1:2024 – 분류, performance testing and marking of high-efficiency filters and media
  • ISO 29463-3:2011Testing flat-sheet filter media
  • ISO 29463-4:2011Scan method for determining leakage of filter elements; confirmed in 2024 while a new edition is under development
  • ISO 29463-5:2022 – MPPS efficiency test method for filter elements
  • ISO 14644-3:2019Test methods for cleanrooms and clean zones, including performance verification relevant to installed systems

연락하세요

가기 전에...

귀하의 프로젝트에 어떤 국제 표준이 적용되는지 확실하지 않음? 당사의 10년 업계 전문 지식을 바탕으로 한 맞춤형 기술 평가를 위해 수석 엔지니어와 상담하세요..

502 나쁜 게이트웨이

502 나쁜 게이트웨이


nginx
*우리는 귀하의 기밀성을 존중하며 모든 정보는 보호됩니다.

글로벌 표준 테스트 시스템으로 품질을 검증하세요

우리 전문가들은 귀하를 위한 맞춤형 솔루션을 설계할 준비가 되어 있습니다.. 귀하의 프로젝트에 대해 알려주십시오., 정확하고 빠르게 품질을 검증해 드립니다..

커스텀 R&디 & 맞춤형 솔루션

커스텀 R&디 & 맞춤형 솔루션

글로벌 스탠다드 준수

글로벌 스탠다드 준수

100% 자체 개발 소프트웨어 시스템

100% 자체 개발 소프트웨어 시스템

원격 교정 & 글로벌 지원

원격 교정 & 글로벌 지원

문의하기

*우리는 귀하의 기밀성을 존중하며 모든 정보는 보호됩니다.

This page has been automatically translated from the English original for convenience. Product models, standards, numerical values and technical limits should be verified against the English version. Please contact SCPUR for project-specific confirmation.