IEST-RP-CC001 is a recommended practice published by the Institute of Environmental Sciences and Technology. It provides guidance on the terminology, 분류, 건설, performance and testing of HEPA and ULPA filters.
Unlike EN 1822 ISO 29463, IEST-RP-CC001 should not be presented as an identical filter-classification system. The required test method, 에어로졸, measurement instrument and acceptance criteria should be selected according to the specified filter type, application and contractual requirement.
반도체 제조
의약품 생산
항공우주 오염 통제
생명공학 연구소
IEST-RP-CC001의 주요 테스트 방법
입자 침투 측정
Filter Performance Testing
Filter performance is evaluated by challenging the filter with a specified test aerosol and comparing the upstream and downstream concentrations. The test method must match the filter type, required efficiency level and specified measurement range.
해당 절차에 따라, particle-counting or photometric methods may be used. The aerosol and instrument should therefore not be selected independently from the required test method.
Overall Efficiency and Penetration
Overall efficiency represents the average performance of the complete filter under the specified airflow and test conditions. The report should identify the aerosol, 기류, measurement method and particle-size basis used for the test.
국부 누출 테스트 (스캔 테스트)
Local leak testing is used to identify defects in the filter media, media-pack seal or frame connection. The scanning method, probe movement, sampling flow and acceptance criterion must follow the selected procedure.
Overall efficiency testing and local leak testing serve different purposes. Passing an overall efficiency test does not by itself confirm that the filter has no local defect.
다른 표준과의 관계
IEST-RP-CC001은 실용적인 지침을 제공하기 위해 국제 여과 표준과 함께 사용되는 경우가 많습니다..
Standard or Practice
Main Role
IEST-RP-CC001
Recommended practice covering HEPA and ULPA filter terminology, 분류, performance and testing
안에 1822
European classification and testing of EPA, HEPA and ULPA filters using MPPS-based methods
ISO 29463
International classification and testing of high-efficiency filters and filter media using MPPS-based methods
ISO 14644-3
Test methods used for cleanroom and clean-zone performance verification, including installed filter-system leakage testing
These documents are related but not interchangeable. The standard or recommended practice specified by the customer, project or regulatory requirement should be used for acceptance.
EN1822 및 ISO29463은 공식 분류 시스템을 정의하지만, IEST-RP-CC001은 오염 제어 산업에서 널리 채택되는 실용적인 지침을 제공합니다..
일반적인 테스트 구성
일반적인 IEST-RP-CC001 테스트 시스템에는 안정적인 입자 제거 성능과 무결성 검증을 보장하는 여러 주요 구성 요소가 포함되어 있습니다..
에어로졸 생성 시스템 (PAO/DOP)
업스트림 및 다운스트림 샘플링
입자 측정 장비
누출 감지용 스캐닝 프로브
필터 제조에 적용
표준화된 절차에 따라 일관된 필터 성능과 안정적인 오염 제어가 보장됩니다..
Manufacturers may use the applicable procedures for:
Production quality control
Filter qualification
Overall efficiency verification
Local integrity testing
Test-data recording and customer documentation
IEST-RP-CC001 테스트 솔루션
IEST-RP-CC001은 필터 무결성 및 효율성을 검증하기 위한 권장 사례를 제공하여 클린룸 성능을 유지하는 데 중요한 역할을 합니다..
우리 전문가들은 귀하를 위한 맞춤형 솔루션을 설계할 준비가 되어 있습니다.. 귀하의 프로젝트에 대해 알려주십시오., 정확하고 빠르게 품질을 검증해 드립니다..
커스텀 R&디 & 맞춤형 솔루션
글로벌 스탠다드 준수
100% 자체 개발 소프트웨어 시스템
원격 교정 & 글로벌 지원
문의하기
*우리는 귀하의 기밀성을 존중하며 모든 정보는 보호됩니다.
가기 전에...
귀하의 프로젝트에 어떤 국제 표준이 적용되는지 확실하지 않음? 당사의 10년 업계 전문 지식을 바탕으로 한 맞춤형 기술 평가를 위해 수석 엔지니어와 상담하세요..
*우리는 귀하의 기밀성을 존중하며 모든 정보는 보호됩니다.
This page has been automatically translated from the English original for convenience. Product models, standards, numerical values and technical limits should be verified against the English version. Please contact SCPUR for project-specific confirmation.