HEPA & ULPA Filter Test Systems

Factory test systems for measuring the efficiency and local penetration of finished high-efficiency filters. Configurations are available for production quality control, integral efficiency measurement and automatic leak scanning according to the required EN 1822 or ISO 29463 procedure.

Advanced Filter Assembly Test Rigs & Systems

Compare SCPUR systems for routine HEPA production screening and MPPS-related HEPA or ULPA testing. The required particle range, detector sensitivity, airflow and scanning arrangement depend on the filter class and test objective.

Showing Slide 1 of 2: SC-L8023U HEPA/ULPA Scanning System

Comprehensive Testing Solutions by Filter Class

Providing rigorous leak scanning and efficiency validation for EPA, HEPA, and ULPA filters, compliant with EN 1822 and ISO 29463.
V Bank & Compact Filters
Recommended: SC-L8023

EPA Filters (E10–E12)

  • V-Bank Filters
  • Flat Panel Filters

Reliable particulate control for semi-critical industrial areas and HVAC final stages, protecting downstream cleanroom systems.

HEPA Filters (H13–H14)
Recommended: SC-L8023

HEPA Filters (H13–H14)

  • HEPA Panels (H13/H14)
  • Fan Filter Units (FFU)

Automatic efficiency measurement and local leak scanning for finished H13 and H14 filters used in cleanroom, pharmaceutical and other controlled applications.

ULPA Filters (U15–U17)
Recommended: SC-L8023U

ULPA Filters (U15–U17)

  • ULPA Panels (U15-U17)
  • MPPS Verification (0.1-0.3µm)

Precise MPPS efficiency mapping and sub-micron scanning for critical semiconductor and pharmaceutical applications.

Engineering for Reliable HEPA Filter Testing

Controlled airflow, aerosol concentration, particle measurement and scanning motion support repeatable factory testing under the selected EN 1822 or ISO 29463 procedure.
Automated Dual Aerosol Switching
Stable Aerosol Generation & Control
Stable upstream aerosol concentration provides consistent challenge conditions throughout efficiency and leak testing.
Portable Sensing Technology SC 8013
Precision XYZ Leak Scanning
High-precision XYZ motion control and synchronized particle sampling provide repeatable full-surface scanning and accurate leak localization.
mpps
MPPS Efficiency Measurement
Multi-channel particle measurement identifies the Most Penetrating Particle Size (MPPS) and evaluates filter efficiency according to the applicable test procedure.
Smart Visualization & Traceability
Complete Traceability & Reporting
Automatically records test data and generates leak maps, inspection records, and standardized reports for production quality traceability.

Applicable Standards

The applicable test method depends on the filter class, required result, aerosol, particle-measurement range, airflow and scanning arrangement.
EN 1822-4
Leak Determination

Leak Determination

Automated scanning for EPA, HEPA, and ULPA filters to verify local integrity and detect leaks.

ISO 29463-4
Leakage Test Methods

Leakage Test Methods

Global standard for determining leakage of filter elements via scan method.

ISO 29463-5
Efficiency Test Methods

Efficiency Test Methods

Overall filter-element efficiency or penetration measurement at the required particle size or MPPS. Filter testing does not by itself verify the cleanliness class of the installed room.

Industry Applications

Meeting strict ISO and GMP standards for Semiconductor, Pharmaceutical, and Manufacturing sectors.
HEPA生成

HEPA/ULPA Manufacturing

Automated production testing for HEPA and ULPA filters, supporting consistent quality control according to EN 1822 and ISO 29463.

半导体

Semiconductor & Microelectronics

Validating HEPA and ULPA filters for wafer fabrication and other high-cleanliness manufacturing environments.

制药厂

Pharmaceutical & Life Sciences

Supporting GMP-compliant cleanrooms with validated HEPA integrity testing and traceable inspection records.

Global Technical Support

SCPUR provides remote diagnostics, operating guidance, training resources and technical support to help customers maintain stable system operation.

Rapid Response Commitment

Responsive Technical Support

Our technical team provides remote assistance to review system status, operating parameters and fault information, helping customers identify and resolve operational issues efficiently.

Cost Efficient Remote Calibration

Remote Diagnostics & Verification Support

Remote diagnostics, parameter review and reference-filter verification help identify system issues and reduce unnecessary service delays. Required instrument calibration remains subject to the applicable calibration and traceability procedures.

Lifelong Standard Compliance

Standard Revision & Upgrade Support

When a test standard is revised, SCPUR evaluates its impact on test procedures, software, instruments and hardware. Where changes are required, an appropriate upgrade solution can be provided.

Intuitive Training Resources

Intuitive Training Resources

Multi-language software interfaces, operating manuals and video tutorials help operators learn the system and perform routine tests more consistently.

Validate Your Quality with Global Standard Testing Systems

Our experts are ready to engineer a custom solution for you. Tell us about your project, and let’s verify your quality with precision and speed.

Custom R&D & Tailored Solutions

Custom R&D & Tailored Solutions

Compliance with Global Standards

Compliance with Global Standards

100% Self developed Software System

100% Self-developed Software System

Remote Calibration & Global Support

Remote Calibration & Global Support

Contact Us

*We respect your confidentiality and all information is protected.

Before You Go...

Unsure which international standard applies to your project? Speak with our senior engineers for a personalized technical assessment based on our 10-year industry expertise.

*We respect your confidentiality and all information is protected.