Таҷрибаи тавсияшуда барои тасниф ва озмоиши филтрҳои самаранок дар муҳити аз ифлосшавӣ назоратшаванда.
Баррасии стандарти IEST-RP-CC001
IEST-RP-CC001 is a recommended practice published by the Institute of Environmental Sciences and Technology. It provides guidance on the terminology, тасниф, сохтмон, performance and testing of HEPA and ULPA filters.
Unlike EN 1822 ва ISO 29463, IEST-RP-CC001 should not be presented as an identical filter-classification system. The required test method, аэрозол, measurement instrument and acceptance criteria should be selected according to the specified filter type, application and contractual requirement.
Истеҳсоли нимноқилҳо
Истеҳсоли дорусозӣ
Назорати ифлосшавии кайҳон
Лабораторияҳои биотехнологӣ
Усулҳои асосии санҷиш дар IEST-RP-CC001
Андозаи воридшавии зарраҳо
Filter Performance Testing
Filter performance is evaluated by challenging the filter with a specified test aerosol and comparing the upstream and downstream concentrations. The test method must match the filter type, required efficiency level and specified measurement range.
Вобаста ба тартиби татбиқшаванда, particle-counting or photometric methods may be used. The aerosol and instrument should therefore not be selected independently from the required test method.
Overall Efficiency and Penetration
Overall efficiency represents the average performance of the complete filter under the specified airflow and test conditions. The report should identify the aerosol, равиши ҳаво, measurement method and particle-size basis used for the test.
Local Leak Testing (Санҷиши скан)
Local leak testing is used to identify defects in the filter media, media-pack seal or frame connection. The scanning method, probe movement, sampling flow and acceptance criterion must follow the selected procedure.
Overall efficiency testing and local leak testing serve different purposes. Passing an overall efficiency test does not by itself confirm that the filter has no local defect.
Recommended practice covering HEPA and ULPA filter terminology, тасниф, performance and testing
ДАР 1822
European classification and testing of EPA, HEPA and ULPA filters using MPPS-based methods
ISO 29463
International classification and testing of high-efficiency filters and filter media using MPPS-based methods
ISO 14644-3
Test methods used for cleanroom and clean-zone performance verification, including installed filter-system leakage testing
These documents are related but not interchangeable. The standard or recommended practice specified by the customer, project or regulatory requirement should be used for acceptance.
This page has been automatically translated from the English original for convenience. Product models, standards, numerical values and technical limits should be verified against the English version. Please contact SCPUR for project-specific confirmation.