High-Efficiency Filters and Filter Media for Removing Particles in Air

Understanding the ISO 29463 standard for evaluating HEPA and ULPA filters.

Хона

>

ISO 29463

Overview of the ISO 29463 Стандарт

Overview of the ISO 29463 Стандарт

ISO 29463 is an international standard that specifies the classification, усулҳои санҷиш, and performance evaluation procedures for HEPA and ULPA filters. The standard is widely used in industries requiring strict air cleanliness.

“ISO 29463 is largely harmonized with the European standard EN 1822 and defines the testing principles used to evaluate high-efficiency air filtration performance.

Semiconductor Facilities

Semiconductor Manufacturing

Pharmaceutical Production

Pharmaceutical Production

Cleanroom Environments

Cleanroom Environments

Key Test Methods in ISO 29463

MPPS Efficiency Measurement

Key Testing Principle: MPPS

A central concept in ISO 29463 is the Most Penetrating Particle Size (MPPS). Instead of evaluating efficiency at a fixed particle size, the filter is tested at the particle size where filtration efficiency is lowest. This ensures that the measured efficiency represents the most critical filtration condition. MPPS testing provides a more accurate assessment of filter performance compared to fixed particle-size testing.

Leak Detection and Integrity Testing

ISO 29463 also specifies procedures for detecting local leakage defects in filter elements. A scanning probe is used to measure particle concentration downstream of the filter surface. Localized increases in particle concentration may indicate defects in the filter media, frame, or sealing areas. Leak detection testing is essential for verifying the integrity of high-efficiency filters before installation in critical environments.

Leak Detection Test

HEPA and ULPA Filter Classification Categories

Based on measured efficiency, filters are classified into different performance categories. Typical classification ranges include:

ClassTypical Efficiency Range
EPAEfficient particulate air filters
HEPAHigh-efficiency particulate air filters
ULPAUltra-low penetration air filters

The classification reflects the filter’s ability to remove airborne particles under standardized testing conditions.

Structure and Parts of the ISO 29463 Стандарт

ISO 29463 is organized into several parts covering classification methods, test procedures, and filter integrity verification. Typical structure includes:

Part

Description

ISO 29463-1

Classification, performance testing, and marking

ISO 29463-2

Aerosol production, measuring equipment, and particle counting methods

ISO 29463-3

Flat sheet filter media testing

ISO 29463-4

Determination of leakage and efficiency

ISO 29463-5

Filter element efficiency testing

These parts collectively define how HEPA and ULPA filters should be tested and classified.

Application in High-Efficiency Filtration

Application in High-Efficiency Filtration

Reliable and repeatable testing conditions are essential to ensure that efficiency and classification results reflect the actual performance of high-efficiency filters. ISO 29463 testing is essential for:

ISO 29463 Testing Solutions

ISO 29463 provides a globally recognized framework for evaluating HEPA and ULPA filter performance. By defining standardized procedures for aerosol generation, particle measurement, and leakage detection, the standard ensures that filter performance results are consistent, comparable, and reliable across laboratories worldwide.

IEST-RP-CC001 Testing Solutions

Relationship to Other Standards

ISO 29463 is closely related to several other filtration standards.

  • Стандарт
    EN1822
  • Application
    European HEPA/ULPA classification
  • Стандарт
    ISO16890
  • Application
    General ventilation air filters
  • Стандарт
    АШРАЕ 52.2
  • Application
    North American HVAC filtration testing

While ISO 16890 and ASHRAE 52.2 focus on general ventilation filters, ISO 29463 specifically addresses high-efficiency cleanroom filtration.

Discuss Your Filtration Testing Requirements

Tell us your filter type, testing standard, and application scenario.

Our engineers will help you identify the most suitable testing solution — from standard systems to fully customized platforms.

Сифати худро бо системаҳои глобалии санҷиши стандартӣ тасдиқ кунед

Мутахассисони мо омодаанд, ки ҳалли фармоиширо барои шумо таҳия кунанд. Дар бораи лоиҳаи худ ба мо нақл кунед, ва биёед сифати шуморо бо дақиқ ва суръат тафтиш кунем.

Фармоишгар Р&Д & Қарорҳои фармоишӣ

Фармоишгар Р&Д & Қарорҳои фармоишӣ

Мутобиқати стандартҳои ҷаҳонӣ

Мутобиқати стандартҳои ҷаҳонӣ

100% Системаи нармафзори худидорашаванда

100% Системаи нармафзори худидорашаванда

Калибрченкунии дурдаст & Дастгирии глобалӣ

Калибрченкунии дурдаст & Дастгирии глобалӣ

Бо мо тамос гиред

*Мо махфияти шуморо эҳтиром мекунем ва ҳама маълумот ҳифз карда мешавад.

Пеш аз рафтан...

Боварӣ надоред, ки кадом стандарти байналмилалӣ ба лоиҳаи шумо татбиқ мешавад? Бо муҳандисони калони мо барои баҳодиҳии техникии фардӣ дар асоси таҷрибаи 10-солаи мо сӯҳбат кунед.

*Мо махфияти шуморо эҳтиром мекунем ва ҳама маълумот ҳифз карда мешавад.