According to the principle of particle impact, JYQ-III Microbial Air Sampler can separate the bacterial particles in the sampled air under the action of air pump. By adopting the slit collection method, the sampled bacterial particles are evenly distributed on the circular ring of the plate culture medium through the slits, and can become bacteria which can be counted by naked eyes after being cultured. In addition, according to the distribution of bacteria, the distribution dynamics of bacteria in the air can also be obtained intuitively.
Availability: | |
---|---|
Quantity: | |
SC-JYQ-III
Scince
According to
GMP , ISO 14698-1/2, GB/T 16293-2010.
Advantages
Single-chip microcomputer control circuit test has the function of delaying starting for 15 seconds, which has the advantages of fast test speed, high efficiency and low error.
Using special suction pump, the noise is smaller.
Application
Widely used in pharmaceutical industry, cosmetics industry, food industry and other production enterprises, drug testing institutes, health and epidemic prevention departments, hospitals, environmental monitoring and other related industries and departments.
Technical Parameters
1. Sampling flow: 50 L/min.
2. Slit width: ≤40mm×0.38mm.
3. Flow velocity: ≥38m/s.
4. Sampling period: 1~99s, which can be set arbitrarily.
5. Petri dish: Φ90*15mm standard universal type.
6. Dimensions: 280*350*280 mm.
7. Weight: 10.0 kg.
Environmental Requirements
1. Temperature: 5℃~35℃;
2. Relative humidity: 20%~75% RH;
3. Power supply: AC 220 V,50 Hz;
4. Maximum power: 100W.
According to
GMP , ISO 14698-1/2, GB/T 16293-2010.
Advantages
Single-chip microcomputer control circuit test has the function of delaying starting for 15 seconds, which has the advantages of fast test speed, high efficiency and low error.
Using special suction pump, the noise is smaller.
Application
Widely used in pharmaceutical industry, cosmetics industry, food industry and other production enterprises, drug testing institutes, health and epidemic prevention departments, hospitals, environmental monitoring and other related industries and departments.
Technical Parameters
1. Sampling flow: 50 L/min.
2. Slit width: ≤40mm×0.38mm.
3. Flow velocity: ≥38m/s.
4. Sampling period: 1~99s, which can be set arbitrarily.
5. Petri dish: Φ90*15mm standard universal type.
6. Dimensions: 280*350*280 mm.
7. Weight: 10.0 kg.
Environmental Requirements
1. Temperature: 5℃~35℃;
2. Relative humidity: 20%~75% RH;
3. Power supply: AC 220 V,50 Hz;
4. Maximum power: 100W.