في 1822 is a European standard series for the classification and performance testing of high-efficiency air filters. It applies to EPA, HEPA and ULPA filters used in ventilation, air-conditioning and technical processes, including cleanroom and pharmaceutical applications.
The standard evaluates performance at the most penetrating particle size, أو MPPS. It should not be described as a general standard for ordinary residential or commercial HVAC filters, and it is not the same as an installed cleanroom integrity test.
تصنيع غرف الأبحاث
الإنتاج الصيدلاني
مرافق أشباه الموصلات
أنظمة الترشيح المعملية
How EN 1822 أعمال الاختبار
Determine the relevant MPPS performance of the filter medium or use the MPPS information required by the test programme.
Install the finished filter in a sealed test rig and establish the specified airflow.
Generate a stable upstream aerosol and confirm the concentration and sampling conditions.
Measure the integral efficiency or penetration of the complete filter at the required particle size or MPPS.
For applicable H and U classes, scan the downstream filter face and relevant sealant areas to identify excessive local penetration.
Record pressure drop, شروط الاختبار, integral results, local results and the final classification.
Filter Groups and Classes
في 1822 separates high-efficiency filters into three groups. The required evidence becomes more demanding as penetration decreases.
Group
فصول
Classification evidence
EPA
E10-E12
Integral efficiency at MPPS. Local leak testing is not required for classification.
HEPA
H13-H14
Integral efficiency and the applicable local leakage requirement.
ULPA
تحت 15- تحت 17
Stricter integral efficiency and local leakage requirements at MPPS.
A report should identify the class, تدفق الهواء الاسمي, test aerosol, MPPS, integral efficiency or penetration and the leak-test method used. Class names should not be converted casually from another standard or from a fixed 0.3 micrometre result.
Integral Efficiency and Local Leakage
Integral efficiency is the average performance of the complete filter. Local leak scanning checks individual positions across the downstream surface. A filter can satisfy its integral efficiency requirement and still fail the local limit because of a pinhole, المتوسطة التالفة, sealant discontinuity or frame-related defect.
These results must therefore remain separate in the report. Group E filters are classified by integral efficiency, while applicable H and U classes also require local leakage evidence.
مولد الهباء الجوي
نظام أخذ العينات المنبع
عداد الجسيمات
مسبار المسح للكشف عن التسرب
نظام تدفق الهواء المتحكم فيه
Factory Testing and Installed Integrity
في 1822 factory testing evaluates an individual filter element before installation. After the filter is mounted in a ceiling, housing or air-handling system, an installed integrity test also checks the gasket, ختم هلام, frame and possible bypass paths. Installed-system verification uses a separate project or cleanroom test procedure and does not replace the manufacturer’s filter classification.
اختيار معدات الاختبار
A complete configuration may require controlled airflow, توليد الهباء الجوي, أخذ العينات المرجعية المنبع, a detector with sufficient particle-size range and sensitivity, automatic scanning motion, leak mapping and report generation. The correct detector and aerosol arrangement depend on the filter class and the lowest penetration that must be measured.
SCPUR configures theSC-L8023 و SC-L8023Usystems according to filter class, أبعاد, تدفق الهواء, نطاق الجسيمات, scanning arrangement and production throughput.
Tell us the filter class, مقاس, rated airflow and required EN 1822 test result. Our engineering team will help define the appropriate system configuration.
تحقق من جودتك من خلال أنظمة الاختبار القياسية العالمية
خبراؤنا على استعداد لتصميم حل مخصص لك. أخبرنا عن مشروعك, ودعنا نتحقق من جودتك بدقة وسرعة.
مخصص ر&د & حلول مخصصة
الامتثال للمعايير العالمية
100% نظام برمجي مطور ذاتيًا
المعايرة عن بعد & الدعم العالمي
اتصل بنا
*نحن نحترم سريتك وجميع المعلومات محمية.
قبل أن تذهب...
غير متأكد من المعيار الدولي الذي ينطبق على مشروعك? تحدث مع كبار المهندسين لدينا للحصول على تقييم فني شخصي بناءً على خبرتنا الصناعية الممتدة على مدار 10 سنوات.
*نحن نحترم سريتك وجميع المعلومات محمية.
This page has been automatically translated from the English original for convenience. Product models, standards, numerical values and technical limits should be verified against the English version. Please contact SCPUR for project-specific confirmation.