Filter Media Testing Guide: Efficiëntie, Pressure Drop and MPPS

Deel:

Inhoudsopgave

Filter media testing compares the material itself before pleating, bonding and framing. It helps manufacturers screen materials and shorten development cycles, but it does not replace testing of the finished filter. A media-efficiency table alone cannot determine a cleanroom class, final product life or leak-free performance.

Five results that matter

Five results that matter

  • Fractional-efficiency curve: Shows how capture performance changes with particle size instead of reducing the result to one particle diameter.
  • Pressure drop at face velocity: The same material can perform very differently at another face velocity, so the test condition must match the intended design.
  • MPPS: HEPA En ULPA media should be evaluated near the most penetrating particle size. MPPS should not automatically be assumed to be 0.3 µm.
  • Before-and-after conditioning: A high initial efficiency in charged synthetic media does not guarantee the same performance after the removable charge is reduced.
  • Batch consistency: Fixed sampling locations and test conditions reveal meaningful variation in raw material, production process and supply batches.

Different applications need different emphasis

Different applications need different emphasis

For general-ventilation synthetic or electret media, compare initial performance, conditioned performance and pressure drop. For glass-fiber, PTFE and other high-efficiency media, MPPS, very low downstream concentration, instrument dynamic range and holder bypass become more important. Engine-intake and gas-turbine media can be screened as flat sheets, but dust capacity, resistance growth and sealing must still be verified on the complete element under the applicable finished-filter standard.

Why can good media still produce a poor filter?

Why can good media still produce a poor filter?

Pleat height and spacing change effective area and airflow distribution. Adhesive lines, frames and seals can introduce local leakage, while assembly stress may damage the media. Media testing therefore answers whether a material deserves to move into the next development stage. Finished-filter testing answers whether the final product meets its declared performance.

What should you check when choosing a media tester?

What should you check when choosing a media tester?

Define the target efficiency range, particle size or aerosol, sample area and face velocity first. Then evaluate upstream and downstream counting capability, dilution, holder sealing, herhaalbaarheid, calibration and data traceability. SCPUR SC-FT-1406D, SC-FT-1406DH En SC-FT-1406DU are configured for flat-sheet media across different efficiency ranges. They are not finished-filter test benches, and selection should start with the sample and test objective rather than the labels HEPA of ULPA alone.

Filter

Neem contact op

Voordat je gaat...

Weet u niet zeker welke internationale standaard van toepassing is op uw project?? Praat met onze senior engineers voor een gepersonaliseerde technische beoordeling op basis van onze 10-jarige branche-expertise.

*Wij respecteren uw vertrouwelijkheid en alle informatie wordt beschermd.

Valideer uw kwaliteit met wereldwijde standaardtestsystemen

Onze experts staan ​​klaar om voor u een oplossing op maat te engineeren. Vertel ons over uw project, en laten we uw kwaliteit met precisie en snelheid verifiëren.

Aangepaste R&D & Op maat gemaakte oplossingen

Aangepaste R&D & Op maat gemaakte oplossingen

Naleving van mondiale normen

Naleving van mondiale normen

100% Zelf ontwikkeld softwaresysteem

100% Zelf ontwikkeld softwaresysteem

Kalibratie op afstand & Wereldwijde ondersteuning

Kalibratie op afstand & Wereldwijde ondersteuning

Neem contact met ons op

*Wij respecteren uw vertrouwelijkheid en alle informatie wordt beschermd.

This page has been automatically translated from the English original for convenience. Product models, standards, numerical values and technical limits should be verified against the English version. Please contact SCPUR for project-specific confirmation.