When it comes to testing HEPA and ULPA filters, two major standards are widely used:
안에 1822 그리고 ISO 29463.
Although they are closely related, there are important differences in their structure, 애플리케이션, and global usage.
This guide explains the key differences to help you understand which standard to use—and why it matters.
1. EN 개요 1822 ISO 29463
안에 1822
- European standard
- Focused on HEPA/ULPA filter testing
- Widely used in Europe and many international projects
ISO 29463
- International standard (based on EN 1822)
- Developed to harmonize global testing methods
- Increasingly adopted worldwide
👉 In simple terms:
ISO 29463 = international version of EN 1822 (with some extensions)
2. Structural Differences
안에 1822 구조
안에 1822 is typically divided into 5 부분품:
- 분류, performance testing
- Aerosol production and measurement
- Flat sheet media testing
- Leak test (스캔 테스트)
- Filter element testing
ISO 29463 구조
ISO 29463 expands this into multiple parts with more detailed guidance, 포함:
- Additional definitions
- Extended testing procedures
- Global harmonization
👉 ISO 29463 is more comprehensive and standardized internationally
3. 분류체계
두 표준 모두 MPPS의 효율성을 기준으로 필터를 분류합니다.:
| Class Type | 안에 1822 | ISO 29463 |
|---|---|---|
| 헤파 | H13~H14 | Same |
| 격노 | U15~U17 | Same |
👉 Classification values are essentially aligned
4. Testing Method Comparison
Similarities
Both standards include:
✔ MPPS determination
✔ Efficiency testing
✔ Leak (scan) 테스트
Differences
| 측면 | 안에 1822 | ISO 29463 |
|---|---|---|
| 범위 | 유럽 중심 | Global |
| Detail level | Moderate | More detailed |
| Standardization | Regional | 국제적인 |
👉 실제로:
Test principles are the same, but ISO 29463 is more standardized globally
5. 누출 테스트 (스캔 테스트): No Real Difference
The most critical test in both standards is the 스캔 테스트.
- Detects local leaks in filters
- Ensures uniform performance
- Required for HEPA/ULPA validation
👉 Equipment requirements are essentially the same for both standards
6. Which Standard Should You Use?
Choose EN 1822 if:
- Your market is Europe
- Your clients specify EN standards
- You work with established HEPA production lines
Choose ISO 29463 if:
- You sell globally
- You need international compliance
- Your clients require ISO certification
👉 Many manufacturers now test according to both standards
7. Practical Challenges in Testing
Regardless of the standard, common challenges include:
- Detecting micro-leaks
- Maintaining stable aerosol concentration
- Achieving consistent scanning speed
- Avoiding false positives
👉 These challenges directly impact test accuracy
8. 권장 테스트 솔루션
To meet both EN 1822 ISO 29463 요구 사항, a reliable scanning system is essential.
그만큼 SC-L8023 Scanning Filter Tester from SCPUR is designed for:
- 고감도 누출 감지
- Precise scanning control
- 안정적이고 반복 가능한 성능
👉 Suitable for both EN 1822 ISO 29463 테스트
9. 결론
안에 1822 ISO 29463 are closely related standards for HEPA and ULPA filter testing.
- 안에 1822 → widely used in Europe
- ISO 29463 → global standard based on EN 1822
👉 In most cases, the testing methods are similar, and the choice depends on your market requirements.
👉 Need a testing solution that meets both EN 1822 ISO 29463? Contact us for expert recommendations.