When it comes to testing HEPA and ULPA filters, two major standards are widely used:
ДАР 1822 and ISO 29463.

Although they are closely related, there are important differences in their structure, application, and global usage.

This guide explains the key differences to help you understand which standard to use—and why it matters.


1. Overview of EN 1822 ва ISO 29463

ДАР 1822
  • European standard
  • Focused on HEPA/ULPA filter testing
  • Widely used in Europe and many international projects

ISO 29463
  • International standard (based on EN 1822)
  • Developed to harmonize global testing methods
  • Increasingly adopted worldwide

👉 In simple terms:
ISO 29463 = international version of EN 1822 (with some extensions)


2. Structural Differences

ДАР 1822 Structure

ДАР 1822 is typically divided into 5 parts:

  1. Classification, performance testing
  2. Aerosol production and measurement
  3. Flat sheet media testing
  4. Leak test (scan test)
  5. Filter element testing

ISO 29463 Structure

ISO 29463 expands this into multiple parts with more detailed guidance, including:

  • Additional definitions
  • Extended testing procedures
  • Global harmonization

👉 ISO 29463 is more comprehensive and standardized internationally


3. Classification System

Both standards classify filters based on efficiency at MPPS:

Class TypeДАР 1822ISO 29463
HEPAH13–H14Same
ULPAU15–U17Same

👉 Classification values are essentially aligned


4. Testing Method Comparison

Similarities

Both standards include:

✔ MPPS determination
✔ Efficiency testing
✔ Leak (scan) озмоиш


Differences
AspectДАР 1822ISO 29463
ScopeEurope-focusedGlobal
Detail levelModerateMore detailed
StandardizationRegionalInternational

👉 In practice:
Test principles are the same, but ISO 29463 is more standardized globally


5. Leak Test (Санҷиши скан): No Real Difference

The most critical test in both standards is the scan test.

  • Detects local leaks in filters
  • Ensures uniform performance
  • Required for HEPA/ULPA validation

👉 Equipment requirements are essentially the same for both standards


6. Which Standard Should You Use?

Choose EN 1822 if:
  • Your market is Europe
  • Your clients specify EN standards
  • You work with established HEPA production lines

Choose ISO 29463 if:
  • You sell globally
  • You need international compliance
  • Your clients require ISO certification

👉 Many manufacturers now test according to both standards


7. Practical Challenges in Testing

Regardless of the standard, common challenges include:

  • Detecting micro-leaks
  • Maintaining stable aerosol concentration
  • Achieving consistent scanning speed
  • Avoiding false positives

👉 These challenges directly impact test accuracy


8. Recommended Testing Solution

To meet both EN 1822 ва ISO 29463 requirements, a reliable scanning system is essential.

The SC-L8023 Scanning Filter Tester from SCPUR is designed for:

  • High-sensitivity leak detection
  • Precise scanning control
  • Stable and repeatable performance

👉 Suitable for both EN 1822 ва ISO 29463 озмоиш


9. Conclusion

ДАР 1822 ва ISO 29463 are closely related standards for HEPA and ULPA filter testing.

  • ДАР 1822 → widely used in Europe
  • ISO 29463 → global standard based on EN 1822

👉 In most cases, the testing methods are similar, and the choice depends on your market requirements.


👉 Need a testing solution that meets both EN 1822 ва ISO 29463? Contact us for expert recommendations.

ISO 29463, ДАР 1822

Get in Touch

Popular Blogs

It seems we can't find what you're looking for.

Пеш аз рафтан...

Боварӣ надоред, ки кадом стандарти байналмилалӣ ба лоиҳаи шумо татбиқ мешавад? Бо муҳандисони калони мо барои баҳодиҳии техникии фардӣ дар асоси таҷрибаи 10-солаи мо сӯҳбат кунед.

*Мо махфияти шуморо эҳтиром мекунем ва ҳама маълумот ҳифз карда мешавад.

Сифати худро бо системаҳои глобалии санҷиши стандартӣ тасдиқ кунед

Мутахассисони мо омодаанд, ки ҳалли фармоиширо барои шумо таҳия кунанд. Дар бораи лоиҳаи худ ба мо нақл кунед, ва биёед сифати шуморо бо дақиқ ва суръат тафтиш кунем.

Фармоишгар Р&Д & Қарорҳои фармоишӣ

Фармоишгар Р&Д & Қарорҳои фармоишӣ

Мутобиқати стандартҳои ҷаҳонӣ

Мутобиқати стандартҳои ҷаҳонӣ

100% Системаи нармафзори худидорашаванда

100% Системаи нармафзори худидорашаванда

Калибрченкунии дурдаст & Дастгирии глобалӣ

Калибрченкунии дурдаст & Дастгирии глобалӣ

Бо мо тамос гиред

*Мо махфияти шуморо эҳтиром мекунем ва ҳама маълумот ҳифз карда мешавад.